Anesthesia Machine with Ventilator

319,005.00 262,710.00

Return & Warranty

The warranty is limited to repair, parts replacement by JAGAS MEDICADENTA CORPORATION.

Warranty product will be null and void if:

  • The product is damaged physically
  • The product is repaired, maintained, modified, and disassembled
    Warranty limitation
  • Warranty product of product is limited to manufacturing defect
  • The warranty doesn’t cover replacement of product
  • Warranty doesn’t cover damages caused due to God and force majeure acts

Dent Art Instruments are warranted for one (1) year. If any of the instruments tarnish, break, chip or bend during any dental procedure. Jagas Medicadenta Corporation will replace the instrument at no charge.

Note:    Defective item must be returned to us for exchange via courier to Jagas Medicadenta Corp. with address #46 Filipinas Ave. Jagas Business Center, United Paranaque Subdivision 5, Sucat, and Paranaque City.

JAGAS MEDICA DENTA CORP (“JMDC”) hereby warrants its DENTAL CHAIR AND UNIT (“product”) free from any defect in the material and workmanship for a pe  riod of twelve (12) months or one (1) year from the date of installation and 3 months for Accessories (Light cure, Ultrasonic Scaler, High speed, and Low Speed).

EXCLUSIONS

BUYER’S REMEDIES

 

This warranty covers defects in manufacturing discovered while using the product as recommended by JMDC. However, this warranty does not cover those defects of deficiencies (including failure to conform to products descriptions or specifications) which results, in whole or in part, from the following:

  1. Negligent or improper storage / handling of the product but the buyer;
  2. Failure of the buyer to prepare the site or provide the power requirement;
  3. Failure of the buyer to provide a good source of air and water for the delivery system (Doctor’s Unit) and to the cuspidor unit (Assistant Unit) resulting to blockages in the tubing, hose or fittings (water retracting valve), any service done will be at the buyers expenses;
  4. The absence of any component or accessory recommended by JMDC, but omitted at the buyer’s direction (ex. Air  filter Regulator and Water filter);
  5. Any alterations of the product by persons other than JMDC;
  6. Using incompatible or defective power supply;
  7. Improper use and maintenance of the product, or failure to comply with any application, instructions or recommendation of JMDC;
  8. Bulb and hand pieces; and
  9. Any other cause beyond reasonable control of JMDC.

After proper determination by JMDC that any of its products fail to meet any of the warranties above-mentioned within the applicable period, JMDC shall correct such defect either, at the following options:

  1. By repairing, adjusting, or replacing any defective product or components thereof; or
  2. By making available at the placed assembly necessary repairs or replacement parts or assemblies.
    Installation, troubleshooting, or repairs are included in this warranty

The remedies set forth herein are subject to the condition that the buyer shall promptly notify JMDC within the aforesaid period of any defects or deficiencies, Thereafter, the buyer shall make the product available for correction at a time and place mutually agreed upon.

 

Anesthesia Machine with Ventilator

Description

AJ-2101A  is an economic type of Anesthesia Machine.

  •          The high-precision Vaporizer is designed with a stable concentration output, automatic compensation for pressure, temperature and flow rate. And it is available to choose one kind of gas from Halothane, Enflurane, Isoflurane, and Sevoflurane, ensuring a successful anesthesia operation.
  •           Reliable pneumatic transmission system.
  •           Economic and proper configuration of technologies, optional as required by the Customer.
  •           Modularized design and upgrading. Upgrading is available as required by the Customer.

TECHNICAL PARAMETERS

Part of Anesthesia

  • Main body: High-strength engineering plastic rack, light, beautiful and corrosion resistant
  • Scope of application: adult, child
  • Gas source: O2: 0.27~0.55MPa
  • Flow meter: O2: 0.1~1.0L/min    1.1~10L/min
  • Flow rate of rapid oxygen supply: 25~75L/min
  • Low oxygen pressure alarm: There will be sound alarm when the oxygen pressure < 0.2MPa
  • Vaporizer: It has the function of automatic compensation based on pressure,temperature,and flow rate. The regulation range of evaporator concentration is 0~5 vol%.
  • Among Halothane,Enflurane,Isoflurane and Sevoflurane,one can be chosen for application as required by the customer.
  • Respiratory circuit working mode: all-close, semi-close, semi-open
  • Releasing Pressure: 0.5~7 kPa
  • Respiratory bellows: bellows for adults, bellows for children
  • Tidal Volume Range: 0~1500 ml

Part of Ventilator

  • Display mode: High-definition4.8”LCD screen display
  • Ventilation  mode: IPPV, MANUAL (Manual monitoring of tidal volume, ventilation volume, respiratory rate)
  • Ventilation parameters         
    • Tidal volume: 50~1500ml
    • Rate: 4~80 bpm
    • I:E: 2:1~1:4
    • Pressure range: 1.0~6.0 kPa
    • Parameters for ventilation monitoring: tidal volume, ventilation volume, IPPV rate, I/E, peak pressure of airway, inspiratory trigger pressure, pressure – time waveform
  • Security Alarm System
    • Airway pressure alarm upper limit setting range:1.0~6.0 kPa
    • Low limit setting range: 0.4~2.0 kPa
    • TV alarm upper limit setting range: 0.5~2.0L
    • Low limit setting range: 0.02~1.0L
    • Sustained high-pressure alarm it will give alarm when stress have consistently been higher than 2.5 kPa
    • Suffocation alarm it will give sound and light alarm if there is no tidal volume input in 15s

Power alarm

  • Power: AC 220V±10%     50Hz±1Hz

Loan Form

Additional information

Weight 190 kg